Inspection Procedure
HINT:
Start the inspection from step 1 when using the hand-held tester and start from step 2 when not using the hand-held tester.
- Check output value of master cylinder pressure sensor.
PREPARATION:
- Connect the hand-held tester to the DLC3.
- Turn the ignition switch ON and push the hand-held tester main switch ON.
- Select the DATA LIST mode on the hand-held tester.
CHECK:
Check that the brake fluid pressure value of the master cylinder pressure sensor observed in the hand-held tester changes when the brake pedal is depressed.
OK:
Brake fluid pressure value should change.
- OK: Replace brake actuator assembly. NOTE: When replacing the brake actuator assembly, perform the zero point calibration (see PRE-CHECK ).
- NG: Go To Next Step
- Check whether or not ECU terminal STP input voltage changes when stop light switch comes on and off.
- NO: Check stop light switch circuit (See PROBLEM SYMPTOMS TABLE ).
- YES: If same code is still output after DTC is deleted, check contact condition of each connection. If connections are normal, ECU may be defective.
NOTE: When replacing the brake actuator assembly, perform the zero point calibration (see PRE-CHECK ).