Data List/Active Test
- DATA LIST
HINT:
With the hand-held tester connected to the DLC3 and the power switch in the ON position, the ECB, ABS, and Enhanced VSC data list can be displayed. Follow the prompts on the tester screen to access the DATA LIST.
DATA LISTItem Measurement Item / Range (Display) Normal Condition Diagnostic Note YAW RATE Yaw rate sensor / Min.: -128 deg/s, Max.: 128 deg/s Min.:-128 deg/s
Max.: 128 deg/s- YAW ZERO VALUE Memorized zero value / Min.:-128 deg/s, Max.: 128 deg/s Min.:-128 degs
Max.: 128 deg/s- STEERING ANG Steering sensor / Min.:-1152 deg, Max.: 1150.875 deg Left turn: Increase Right turn: Decrease - 1 SYS BRAKE 1 system brake / OPERATE or BEFORE OPERATE: During operation - REGEN CO OPRT Regenerate co operation / OPERATE or BEFORE OPERATE: During operation - AIR BLD SUPPORT Air bleed availability / SUPPORT or NOT SUP SUPPORT: During support - PKB SW Parking brake switch / ON or OFF ON: Parking brake applied
OFF: Parking brake released- STOP LIGHT SW Stop lamp switch / ON or OFF ON: Brake pedal depressed
OFF: Brake pedal released- - TEST MODE Test mode / NORMAL or TEST NORMAL: Normal mode
TEST: During test mode- RESERVOIR SW Reservoir level warning switch / ON or OFF ON: Reservoir level Normal
NG: Reservoir level Low- WHEEL SPD FR Wheel speed sensor (FR) reading / min.: 0 km/h (0 MPH), max.: 326 km/h (202 MPH) Actual wheel speed Similar speed as indicated on speedometer WHEEL SPD FL Wheel speed sensor (FL) reading / min.: 0 km/h (0 MPH), max.: 326 km/h (202 MPH) Actual wheel speed Similar speed as indicated on speedometer WHEEL SPD RR Wheel speed sensor (RR) reading / min.: 0 km/h (0 MPH), max.: 326 km/h (202 MPH) Actual wheel speed Similar speed as indicated on speedometer WHEEL SPD RL Wheel speed sensor (RL) reading / min.: 0 km/h (0 MPH), max.: 326 km/h (202 MPH) Actual wheel speed Similar speed as indicated on speedometer VEHICLE SPD Maximum wheel speed sensor reading / min.: 0 km/h (0 MPH), max.: 326 km/h (202 MPH) Actual vehicle speed Speed indicated on speedometer IG VOLTAGE ECU power supply voltage TOO HIGH / TOO LOW / NORMAL TOO HIGH: 9.5 V or over
NORMAL: 9.5 V TOO
LOW: Below 9.5 V- DECELERAT SENS Deceleration sensor 1 reading / min.: -1.869 G, max.: 1.869 G Approximately 0 +/- 0.13 G at still condition Reading changes when vehicle is bounced DECELERAT SENS2 Deceleration sensor 2 reading / min.: -1.869 G, max.: 1.869 G Approximately 0 +/- 0.13 G at still condition Reading changes when vehicle is bounced MAS CYL PRS 1 Master cylinder pressure sensor 1 reading / min.: 0 V, max.: 5 V When brake pedal is released: 0.3 to 0.9 V Reading increases when brake pedal is depressed MAS CYL PRS 2 Master cylinder pressure sensor 2 reading / min.: 0 V, max.: 5 V When brake pedal is released: 0.3 to 0.9 V Reading increases when brake pedal is depressed SLAFR CUR Current of SLAFR solenoid / min.: 0 A, max.: 3 A When brake pedal is released: 0 A - SLAFL CUR Current of SLAFL solenoid / min.: 0 A, max.: 3 A When brake pedal is released: 0 A - SLARR CUR Current of SLARR solenoid / min.: 0 A, max.: 3 A When brake pedal is released: 0 A - SLARL CUR Current of SLARL solenoid / min.: 0 A, max.: 3 A When brake pedal is released: 0 A - SLRFR CUR Current of SLRFR solenoid / min.: 0 A, max.: 3 A When brake pedal is released: 0 A - SLRFL CUR Current of SLRFL solenoid / min.: 0 A, max.: 3 A When brake pedal is released: 0 A - SLRRR CUR Current of SLRRR solenoid / min.: 0 A, max.: 3 A When brake pedal is released: 0 A - SLRRL CUR Current of SLRRL solenoid / min.: 0 A, max.: 3 A When brake pedal is released: 0 A - PEDAL STROKE Stroke sensor / min.: 0 V, max.: 5 V When brake pedal is released: 0.7 to 1.3 V - PEDAL STROKE 2 Stroke sensor 2 / min.: 0 V, max.: 5 V When brake pedal is released: 3.7 to 4.3 V - MC 2 MC2 / ON or OFF ON: Operate - MC 1 MC1 / ON or OFF ON: Operate - SSC SSC / ON or OFF ON: Operate - PATTERN A pattern drive is under enforcement / ON or OFF ON: Operate - MAIN RELAY 2 Main relay 2 for ECB / ON or OFF ON: Operate - MAIN RELAY 1 Main relay 1 for ECB / ON or OFF ON: Operate - ACC PRESS SENS 1 Accumulator pressure sensor 1 / min.: 0 V, max.: 5 V Specified value: 3.2 to 4.0 V - FR PRESS SENS Front Right pressure sensor / min.: 0 V, max.: 5 V When brake pedal is released: 0.3 to 0.9 V - FL PRESS SENS Front Left pressure sensor / min. 0 V, max.: 5 V When brake pedal is released: 0.3 to 0.9 V - RR PRESS SENS Rear Right pressure sensor / min.: 0 V, max.: 5 V When brake pedal is released: 0.3 to 0.9 V - RL PRESS SENS Rear Left pressure sensor / min. 0 V, max.: 5 V When brake pedal is released: 0.3 to 0.9 V - MOTOR RELAY 2 Motor relay 2 / ON or OFF ON: Motor relay ON - MOTOR RELAY 1 Motor relay 1 / ON or OFF ON: Motor relay ON - VSC Existence of VSC / WITH or WITHOUT WITH: WITH Enhanced VSC System - 2 FRAMES There is two or more frame for freeze frame data / YES or NO YES: There are two or more freeze frame data - REGEN TORQ FR Regenerative request torque (FR) / min.: 0 N.m, max.: 4080 N.m ECB is not operate: 0 N.m - REGEN TORQ FL Regenerative request torque (FL)/min.: 0 N.m, max.: 4080 N.m ECB is not operate: 0 N.m - REGEN TORQ RR Regenerative request torque (RR) / min.: 0 N.m, max.: 4080 N.m - - REGEN TORQ RL Regenerative request torque (RL) / min.: 0 N.m, max.: 4080 N.m - - SPD SEN FR FR speed sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - SPD SEN FL FL speed sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - SPD SEN RR RR speed sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - SPD SEN RL RL speed sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - YAW RATE SEN Yaw rate sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - DECELE SEN Deceleration sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - STEERING SEN Steering sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - M/C SEN 1 Master cylinder pressure sensor 1 open detection / OPN-DET or NORMAL NORMAL: Normal condition - M/C SEN 2 Master cylinder pressure sensor 2 open detection / OPN-DET or NORMAL NORMAL: Normal condition - STROKE SEN 1 Stroke sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - FR W/C SEN FR wheel cylinder pressure sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - FL W/C SEN FL wheel cylinder pressure sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - RR W/C SEN RR wheel cylinder pressure sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - RL W/C SEN RL wheel cylinder pressure sensor open detection / OPN-DET or NORMAL NORMAL: Normal condition - HV COM HV communication open detection / OPN-DET or NORMAL NORMAL: Normal condition - ACC SEN Accumulator pressure sensor open detection NORMAL: Normal condition - BUZZER Buzzer / ON or OFF ON: Operate - RESERVOIR SW Reservoir level warning switch / ON or OFF ON: Operate - SHIFT POSITION Shift position / FAIL / L / 2 / 3/4/D (M)/R/P.N - - VSC/TRC OFF SW TRAC control switch / ON or OFF ON: TRAC control switch ON - STOP LIGHT SW Stop light switch / ON or OFF ON: Operate - SYSTEM SYSTEM / ABS / VSC (TRAC) / BA / HAB / FAIL SAFE / PB / NOSYS - - #IG ON # IG ON / 0-31 0 - STEERING ANG Steering sensor / Min.:-1152deg, Max.: 1150.875 deg Left turn: Increase Right turn: Decrease - YAW RATE Yaw rate sensor/ Min.:-128deg/s, Max.: 128 deg/s Min.: -128 deg/s Max.: 128 deg/s - MAS CYL PRESS Master cylinder pressure / min.: 0 V, max.: 5 V When brake pedal is released: 0.3 to 0.9 V Reading increases when brake pedal is depressed PEDAL STROKE Stroke sensor / min.: 0 V, max.: 5 V When brake pedal is released (SKS1): 0.7 to 1.5 V When brake pedal is released (SKS2): 3.7 to 4.3 V - THROTTLE Throttle position sensor / min.: 0 deg, max.: 125 deg Release accelerator pedal: Approx. 0 deg. Depress accelerator pedal: Approx. 90 deg. - MAS PRESS GRADE Master pressure sensor grade / min.: -30Mpa/s, max.: 225 Mpa/s When brake pedal is released: 0MPa - G (RIGHT & LEFT) Right and left G / min.: -1.869 G, max.: 1.869 G Approximately 0 +/- 0.13 G at still condition - G (BACK & FORTH) Back and forth G / min.: -1.869 G, max.: 1.869 G Approximately 0 +/- 0.13 G at still condition - SPD GRADE Vehicle speed grade /min.: -1.869 G, max.: 1.869 G Approximately 0 +/- 0.13 G at still condition - # CODES Number of DTC recorded / min.: 0, max.: 255 Min.: 0, max.: 39 - - ACTIVE TEST
HINT:
Performing the ACTIVE TEST using the hand-held tester allows the relay and actuator, etc. to operate without removing any parts. Performing the ACTIVE TEST as the first step of troubleshooting is one of the methods to shorten labor time.
It is possible to display the DATA LIST during the ACTIVE TEST.
- Connect the hand-held tester to the DLC3.
- Turn the power switch ON (READY).
- According to the display on the tester, perform the "ACTIVE TEST".
HINT:
Ignition switch must be turned to the ON position to proceed to the Active Test using the hand-held tester.
ACTIVE TEST REFERENCEItem Vehicle Condition / Test Details Diagnostic Note ABS WARN LIGHT Turns ABS warning light ON / OFF Observe combination meter VSC WARN LIGHT Turns VSC warning light ON / OFF Observe combination meter SLIP INDI LIGHT Turns SLIP indicator light ON / OFF Observe combination meter BRAKE WARN LIGHT Turns BRAKE warning light ON / OFF Observe combination meter VSC/BR WARN BUZ Turns VSC / BRAKE warning buzzer ON / OFF Buzzer can be heard ECB INDI LIGHT Turns Brake Control warning light ON / OFF Observe combination meter MAIN RELAY 1 Turns MAIN RELAY 1 ON / OFF Operation of solenoid (clicking sound) can be heard MAIN RELAY 2 Turns MAIN RELAY 2 ON / OFF Operation of solenoid (clicking sound) can be heard MC1 Turns Master cut valve 1 activation ON / OFF Operation of solenoid (clicking sound) can be heard MC2 Turns Master cut valve 2 activation ON / OFF Operation of solenoid (clicking sound) can be heard MOTOR RELAY 1 Turns MOTOR RELAY 1 ON / OFF Operation of solenoid (clicking sound) can be heard MOTOR RELAY 2 Turns MOTOR RELAY 2 ON / OFF Operation of solenoid (clicking sound) can be heard ECB INVALID Turns ECB invalid ON / OFF Operation of solenoid (clicking sound) can be heard ACC PATTERN Actuator air bleeding pattern activation ON / OFF Operation of solenoid (clicking sound) can be heard SCC PATTERN Stroke simulator cut valve pattern activation ON / OFF Operation of solenoid (clicking sound) can be heard POWER SUPPLY 1 Power supply air bleeding pattern activation 1 ON / OFF Operation of solenoid (clicking sound) can be heard POWER SUPPLY 2 Power supply air bleeding pattern activation 2 ON / OFF Operation of solenoid (clicking sound) can be heard RL AIR BLEEDING RL wheel air bleeding pattern activation ON / OFF Operation of solenoid (clicking sound) can be heard RR AIR BLEEDING RR wheel air bleeding pattern activation ON / OFF Operation of solenoid (clicking sound) can be heard ZERO DOWN Accumulator zero down activation ON / OFF Operation of solenoid (clicking sound) can be heard PUMP PATTERN Pump check pattern activation ON / OFF Operation of solenoid (clicking sound) can be heard DRAIN PATTERN Drain system air bleeding pattern activation ON / OFF Operation of solenoid (clicking sound) can be heard