Inspection Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR TRANSMISSION CONTROL SWITCH-BODY GROUND)
- Disconnect the transmission control switch connector.
- Measure the resistance according to the value (s) in the table below.
Standard:
SPECIFIED CONDITIONTester Connection Specified Condition 6 - Body ground Below 1Ω
- NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (See ELECTRONIC CIRCUIT INSPECTION PROCEDURE )
- OK: GO TO NEXT STEP.
- INSPECT TRANSMISSION CONTROL SWITCH
- Measure the resistance according to the value (s) in the table below.
Standard:
SPECIFIED CONDITIONSwitch Condition Tester Connection Specified Condition Press continuously transmission control switch 2-6 Below 1Ω Release transmission control switch uarr 10 kΩ or higher
- NG: REPLACE TRANSMISSION CONTROL SWITCH (See COMPONENTS )
- OK: GO TO NEXT STEP.
- Measure the resistance according to the value (s) in the table below.
- CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH-ECM)
- Connect the transmission control switch connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value (s) in the table below.
Standard:
- NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (See ELECTRONIC CIRCUIT INSPECTION PROCEDURE )
- OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (See PROBLEM SYMPTOMS TABLE )