LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2004 >> Highlander Limited, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 935 (General Precautions) >> Precaution For HVAC Service Equipment >> Vacuum Pump

Vacuum Pump

WARNING: This page is about a different car, the 2013 Nissan Armada. However, it is still accessible from the selected car via links, so may be relevant.

The oil contained inside the vacuum pump is not compatible with the specified oil for HFC-134a (R-134a) A/C systems. The vent side of the vacuum pump is exposed to atmospheric pressure so the vacuum pump oil may migrate out of the pump into the service hose. This is possible when the pump is switched off after evacuation (vacuuming) and hose is connected to it.

To prevent this migration, use a manual valve situated near the hose-to-pump connection, as follows.

Some one-way valves open when vacuum is applied and close under a no vacuum condition. Such valves may restrict the pump's ability to pull a deep vacuum and are not recommended.

Fig 1: Identifying Isolator Valve Open And Close Position
G04903131Courtesy of NISSAN NORTH AMERICA, INC.