LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2004 >> Highlander Limited, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 923 (Power Window Control System) >> DTC/Circuit Diagnosis >> Power Window Serial Link >> Power Window Main Switch >> POWER WINDOW MAIN SWITCH: Diagnosis Procedure

POWER WINDOW MAIN SWITCH: Diagnosis Procedure

WARNING: This page is about a different car, the 2013 Nissan Armada. However, it is still accessible from the selected car via links, so may be relevant.

Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".

  1. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL 
    1. Remove Intelligent Key or ignition key, and close front door LH and RH.
    2. Check signal between BCM connector and ground with oscilloscope when door lock and unlock switch (LH and RH) is turned to "LOCK" or "UNLOCK".
    3. Check that signals which are shown in the figure below can be detected during 10 second just after door lock and unlock switch (LH and RH) is turned to "LOCK" or "UNLOCK".
      Fig 1: Checking Signal Between BCM Connector And Ground
      G04902785Courtesy of NISSAN NORTH AMERICA, INC.
      Terminal Signal (Reference value)
      (+) (-)
      BCM connector Terminal
      M18 22 Ground
      G04877061

      Is the inspection result normal? 

      YES: Power window serial link is OK.

      NO: GO TO 2

  2. CHECK POWER WINDOW SERIAL LINK CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect BCM and main power window and door lock/unlock switch.
    3. Check continuity between BCM connector and main power window and door lock/unlock switch connector.
      BCM connector Terminal Main power window and door lock/unlock switch connector Terminal Continuity
      M18 (A) 22 D7 (B) 14 Yes
      Fig 2: Checking Continuity Between BCM Connector And Main Power Window And Door Lock/Unlock Switch Connector
      G05382363Courtesy of NISSAN NORTH AMERICA, INC.
    4. Check continuity between BCM connector and ground.
      BCM connector Terminal Ground Continuity
      M18 (A) 22 No

      Is the inspection result normal? 

      YES: Replace main power window and door lock/unlock switch. Refer to "REMOVAL AND INSTALLATION ".

      NO: Repair or replace harness.