Inspection Procedure
- PERFORM ACTIVE TEST BY OBD II SCAN TOOL OR HAND-HELD TESTER
- Check driver seat belt warning operation.
- Connect the OBD II scan tool or hand-held tester to DLC3.
- Turn the ignition switch ON and push the OBD II scan tool or hand-held tester main switch ON.
- Select the ACTIVE TEST mode on the OBD II scan tool or hand-held tester.
- Check that the driver seat belt warning operation.
- NG: CHECK AND REPLACE COMBINATION METER ASSEMBLY
- OK: GO TO NEXT STEP
- Check driver seat belt warning operation.
- READ VALUE OF OBD II SCAN TOOL OR HAND-HELD TESTER
- Check output value of driver side buckle switch.
- Connect the OBD II scan tool or hand-held tester to DLC3.
- Turn the ignition switch ON and push the OBD II scan tool or hand-held tester main switch ON.
- Select the DATA LIST mode on the OBD II scan tool or hand-held tester.
- Check the driver buckle switch using DATA LIST.
- OK: GO TO STEP 5
- NG: GO TO NEXT STEP
- Check output value of driver side buckle switch.
- INSPECT FRONT SEAT INNER BELT ASSEMBLY LH (BUCKLE SWITCH)
- Disconnect the connector from seat belt inner belt RH.
- Check continuity between terminals 1 and 4 when buckle switch condition is as shown in DRIVERS BUCKLE SWITCH SPECIFICATIONS table.
DRIVERS BUCKLE SWITCH SPECIFICATIONSCondition Specified Condition ON (Seat Belt Unfastened) Continuity OFF (Seat Belt Fastened) No Continuity Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- NG: REPLACE FRONT SEAT INNER BELT ASSEMBLY LH
- OK: GO TO NEXT STEP
- CHECK HARNESS AND CONNECTOR (BETWEEN BODY ECU AND FRONT SEAT BELT INNER LH)
- NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
- OK: CHECK AND REPLACE MULTIPLEX NETWORK BODY ECU
- CHECK THAT MALFUNCTION DISAPPEARS WHEN A KNOWN GOOD COMBINATION METER IS INSTALLED
- Check that malfunction disappears when a known good combination meter is installed.
- Malfunction does not disappear, proceed to A.
- Malfunction disappears, proceed to B.
- A: CHECK AND REPLACE MULTIPLEX NETWORK BODY ECU
- B: CHECK AND REPLACE COMBINATION METER ASSEMBLY
- Check that malfunction disappears when a known good combination meter is installed.