Inspection Procedure
- Inspect Fuse (ECU-B, DOME, IG1)
- Check that continuity exists of ECU-B fuse.
- Check that continuity exists of DOME fuse.
- Check that continuity exists of HTR fuse.
- OK: Go To Step 2 , (Check Combination Meter Assy (Power Source Circuit).
- NG: Replace Fuse
- Check Combination Meter Assy (Power Source Circuit)
- Check voltage.
- Disconnect the "C11" connector from combination meter.
- Measure voltage between terminals C11-2, C11-12 of combination meter connector and body ground.
Voltage: 10-14 V
- Turn ignition switch ON.
- Measure voltage between terminals C11-1, C11-13 of combination meter connector and body ground.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Voltage: 10-14 V
- OK: Go To Step 3 , (Check Combination Meter Assy (Ground Circuit).
- NG: Repair Or Replace Harness Or Connector
- Check voltage.
- Check Combination Meter Assy (Ground Circuit)
- Check continuity.
- Disconnect the "C11" connector from combination meter.
- Check continuity between terminals C11-11, C11-22 of combination meter connector and body ground.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: Continuity exists
- OK: Check And Replace Combination Meter Assy
- NG: Repair Or Replace Harness Or Connector
- Check continuity.