LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2002 >> Echo L4-1.5L (1NZ-FE) >> Repair and Diagnosis >> Heating and Air Conditioning >> Expansion Valve >> Testing and Inspection

Expansion Valve: Testing and Inspection

ON-VEHICLE INSPECTION

1. CHECK QUANTITY OF GAS DURING REFRIGERATION CYCLE
2. SET ON MANIFOLD GAUGE SET

3. RUN ENGINE
Run the engine at 1,500 rpm for at least 5 minutes.
Then check that the high pressure reading is 1.37 - 1.57 MPa (14-16 kgf/sq.cm , 199 - 228 psi).

4. CHECK EXPANSION VALVE
If the expansion valve is faulty, the low pressure reading will drop to 0 kPa (0 kgf/sq.cm , 0 psi).

HINT: When the low pressure drops to 0 kPa (0 kgf/sq.cm , 0 psi), check the receiver's IN and OUT sides is no temperature difference.