A3 A/C SINGLE PRESSURE SW [A/C TRIPLE PRESSURE SW]
3 - 2 : Open below approx. 12.5 kgf/sq.cm (178 psi, 1225 kpa)
: Close above approx. 15.5 kgf/sq.cm (220 psi, 1520 kpa)

W3 WATER TEMP. SW
2 - 1 : Open below approx. 83 °C (181.4 °F)
: Close above approx. 90 °C (194 °F)