Seat Belt Warning Occupant Detection Sensor
Disconnect 2-pin Black electrical harness connector from occupant detection sensor located under passenger seat. Using an ohmmeter, check that continuity exists between occupant detection sensor terminals while depressing sensing pad. See Fig 1. If continuity is not as specified, replace occupant detection sensor.