Automatic Disconnect Differential Actuator
WARNING: This page is about a different variant/trim than selected.
NOTE:
For circuit reference, see CONNECTOR IDENTIFICATION and/or WIRING DIAGRAMS
.
- Disconnect actuator connector. Measure resistance between terminal Nos. 2 and 6. See Figure. Resistance should be 0.3-100 ohms. Measure resistance between terminal Nos. 2 and 6 and ground. Resistance should be more than 0.5 ohms. If resistance value is not as specified, replace actuator assembly.
- Apply battery positive voltage to actuator terminal No. 2 and ground actuator terminal No. 6. See Figure. Listen for actuator engagement operation. Using an ohmmeter, check for continuity between actuator terminal Nos. 3 and 4. If there is no continuity, replace actuator.
- Apply battery positive voltage to actuator terminal No. 6 and ground actuator terminal No. 2. Listen for actuator disengagement operation. Using an ohmmeter, check that there is no continuity between actuator terminals No. 3 and 4. If there is continuity, replace actuator.