LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2001 >> Sienna CE >> Repair and Diagnosis >> External Pages >> Different car >> Section 358 (Air Conditioning System - Diagnostics) >> Circuit Inspection >> DTC 13: Evaporator Temperature Sensor Circuit >> Wiring Diagram

DTC 13: Evaporator Temperature Sensor Circuit: Wiring Diagram

WARNING: This page is about a different car, the 2002 Toyota Prius. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Evaporator Temperature Sensor Circuit
G01112343Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  1. Check voltage between terminals TE and SGTE of A/C amplifier connector. 
    Fig 2: Locating A/C Amplifier Terminals TE & SGTE
    G01112344Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    Preparation

    1. Remove center cluster module control with connectors still connected.
    2. Turn ignition switch ON.
      NOTE: As the temperature increases, the voltage decreases.

      Check:  Measure voltage between terminals TE and SGTE of A/C amplifier connector at each temperature. If OK  , voltage at 0 °C (32 °F) : 2.0 - 2.4 V, at 15 °C (59 °F) : 1.4 - 1.8 V.

    1. NG: Go to step   2 . 
    2. If OK  , proceed to next circuit inspection shown on problem symptoms table. See PROBLEM SYMPTOMS TABLE . However, if DTC 13 is displayed, check and replace A/C amplifier.
  2. Check evaporator temperature sensor. 

    PREPARATION:  Remove evaporator temperature sensor. See step 2 of AIR CONDITIONING UNIT DISASSEMBLY .

    NOTE: As the temperature increases, the voltage decreases.

    Check:  resistance between terminals 1 and 2 of evaporator temperature sensor connector at each temperature. If OK  , resistance at 0 °C (32 °F) : 4.6. - 5.1 kΩ, at 15 °C (59 °F) : 2.1 - 2.6 kΩ.

    Fig 3: Testing Evaporator Temperature Sensor
    G01112345Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. NG:  Replace evaporator temperature sensor.
    2. OK: Go to step   3 . 
  3. Check harness and connector between A/C amplifier and evaporator temperature sensor  . See HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION .
    1. NG:  Repair or replace harness or connector.
    2. If OK  , check and replace A/C amplifier.