DTC 13: Evaporator Temperature Sensor Circuit: Wiring Diagram
WARNING: This page is about a different car, the 2002 Toyota Prius. However, it is still accessible from the selected car via links, so may be relevant.
- Check voltage between terminals TE and SGTE of A/C amplifier connector.
Preparation
- Remove center cluster module control with connectors still connected.
- Turn ignition switch ON.NOTE: As the temperature increases, the voltage decreases.
Check: Measure voltage between terminals TE and SGTE of A/C amplifier connector at each temperature. If OK , voltage at 0 °C (32 °F) : 2.0 - 2.4 V, at 15 °C (59 °F) : 1.4 - 1.8 V.
- NG: Go to step 2 .
- If OK , proceed to next circuit inspection shown on problem symptoms table. See PROBLEM SYMPTOMS TABLE . However, if DTC 13 is displayed, check and replace A/C amplifier.
- Check evaporator temperature sensor.
PREPARATION: Remove evaporator temperature sensor. See step 2 of AIR CONDITIONING UNIT DISASSEMBLY .
NOTE: As the temperature increases, the voltage decreases.Check: resistance between terminals 1 and 2 of evaporator temperature sensor connector at each temperature. If OK , resistance at 0 °C (32 °F) : 4.6. - 5.1 kΩ, at 15 °C (59 °F) : 2.1 - 2.6 kΩ.
- NG: Replace evaporator temperature sensor.
- OK: Go to step 3 .
- Check harness and connector between A/C amplifier and evaporator temperature sensor
. See
HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION
.
- NG: Repair or replace harness or connector.
- If OK , check and replace A/C amplifier.