Inspection Procedure

WARNING: This page is about a different car, the 2002 Toyota Prius. However, it is still accessible from the selected car via links, so may be relevant.
  1. Check blower motor. 

    Preparation:  Remove blower motor. See BLOWER UNIT DISASSEMBLY .

    Check:  Connect positive (+) lead connected to terminal 2 of blower motor connector, negative (-) lead to terminal 1. If OK  , blower motor operates smoothly.

    Fig 1: Testing Blower Motor
    G01112417Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. NG:  Replace blower motor.
    2. If OK  , go to step  2.
  2. Check harness and connector between battery and blower motor, blower motor and body ground  . See HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION .
    1. NG:  Repair or replace harness or connector.
    2. If OK  , go to step  3.
  3. Check harness and connector between blower motor linear controller and A/C amplifier  . See HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION .
    1. NG:  Repair or replace harness or connector.
    2. If OK  , go to step  4.
  4. Check A/C amplifier.  . See HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION .
    1. NG:  Replace A/C amplifier.
    2. If OK  , replace blower motor linear controller.