Inspection Procedure
WARNING: This page is about a different car, the 2002 Toyota Prius. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Read freeze frame data using a TOYOTA hand-held tester or OBD II scan tool. Because freeze frame data records the battery condition when the malfunction is detected. When troubleshooting, this is useful for knowing the battery condition.
- Check voltage between terminal AM of Battery ECU connector and body ground.
PREPARATION:
Remove the luggage trim.
CHECK:
Measure the voltage between terminal AM of the Battery ECU connector and body ground.
OK:
Voltage: 9 - 14 V .
- OK: Check and replace Battery ECU . See page HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE .
- NG: Go to next step.
- Check HV fuse of engine room J/B.
PREPARATION:
Remove the HV fuse from the engine room J/B.
CHECK:
Check the continuity of the HV fuse.
OK:
Continuity .
- NG: Check for short in all harness and components connected to HV fuse.
- OK: Go to next step.
Check and repair harness or connector between battery and HV fuse, and HV fuse and Battery ECU . See page HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE .