Inspection Procedure
WARNING: This page is about a different car, the 2002 Toyota Prius. However, it is still accessible from the selected car via links, so may be relevant.
- Check for open, short and +B short in wire harness between HV ECU MSIV and MIVG terminals and converter & inverter assembly M-SINV and M-GIVN terminals
. See
HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION
.NOTE: The motor inverter stop signal circuit has +B short if the voltage between the HV ECU MSIV or MIGV terminal and body ground is always more than 13 V with the ignition ON ("READY" light OFF).
- NG: Repair or replace wire harness.
- OK: Replace converter & inverter assembly.