Inspection Procedure
Start the inspection from step 1 in case of using the hand-held tester and start from step 2 in case of not using hand-held tester.
- Check precharge pump motor operation.
Preparation:
- Connect the hand-held tester to the DLC3.
- Turn the ignition switch ON and push the hand-held tester main switch ON.
- Select the ACTIVE TEST mode on the hand-held tester.
Check: the operation sound of the precharge pump motor when operating it with the hand-held tester.
OK: The operation sound of the precharge pump motor should be heard.
NG: Go to step 3.
OK: If the same code is still output after the DTC is deleted, check the contact condition of each connection. If the connections are normal, the ECU may be defective.
- Check precharge pump motor operation.
Preparation: Disconnect the connector from the precharge pump motor.
Check: Connect ML+ (2) terminal to the battery positive (+) and ML- (1) terminal to the battery negative (-).
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: The operation sound of the pump motor should be heard.
NG: Check and replace precharge pump.
If OK , go to step 3.
- Check for open and short circuit in harness and connector between precharge pump and ABS & BA & TRAC & VSC ECU. See HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE .
NG: Repair or replace harness and connector.
OK: Check and replace ABS & BA & TRAC & VSC ECU.