Turbo Meter Drive Circuit (Supra)
- Disconnect turbo pressure sensor connector. Remove instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Inspect wire harness connectors/terminals for damage or poor connections.
- Using DVOM, check wiring harness connector terminals for correct values. See Fig 1. See TURBO METER DRIVE CIRCUIT SPECIFICATIONS TABLE (SUPRA) . If values are not as specified, replace rheostat.
TURBO METER DRIVE CIRCUIT SPECIFICATIONS (SUPRA)
| Connector-Terminal Number |
Specified Value |
| Resistance Check |
| "A"-8 - Ground |
Continuity |
| "E"-1 - Ground |
Continuity |
| "E"-2 - Ground |
Continuity |
| "E"-3 - Ground |
Continuity |
| Voltage Check |
| "C"-8 - Ground |
Zero Volts |
| "C"-8 - Ground |
Battery Voltage |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002