LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 1990 >> Corolla Base, Automatic >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel - Standard >> Testing >> Temperature Gauge & Sender >> Temperature Sending Unit Resistance Test

Temperature Sending Unit Resistance Test

Remove temperature sending unit. Connect ohmmeter between sender terminal and body of sender. Check resistance while heating sender in water. See COOLANT TEMPERATURE SENDER RESISTANCE SPECIFICATIONS  table. Replace sender if inaccurate.

COOLANT TEMPERATURE SENDER RESISTANCE SPECIFICATIONS

Application Resistance (Ohms)
Camry, Corolla & Cressida
122°F (50°C) (1) 190-260
140°F (60°C) (2) 152-154
239°F (115°C) (1) 24-28
239°F (115°C) (2) 23-28
Celica, Land Cruiser & Tercel
122°F (50°C) 190-260
239°F (115°C) 24-28
Pickup & 4Runner
140°F (60°C) (2) 143-174
239°F (115°C) 22-26
Supra
122°F (50°C) (1) 162-232
140°F (60°C) (2) 150-156
239°F (115°C) (1) 24-29
239°F (115°C) (2) 17-21
(1) For Nippondenso gauge.
(2) For Yazaki gauge.