Fuel Tank Sending Unit: Camry
Connect a series of 3 1.5-volt dry cell batteries. Connect positive lead of batteries to terminal No. 2 and negative lead to terminal No. 4. Check that voltage changes between terminals No. 3 and 4 as sending unit float is moved from full to empty positions. With ignition on, measure voltage at terminals No. 3 and 4 of sending unit connector and ground.
CAMRY FUEL TANK SENDING UNIT OUTPUT VOLTAGES
| Fuel Level | Voltage |
|---|---|
| Full | 4.5 |
| 1/2 Tank | 2.5 |
| Empty | .3 |