Hydraulic Valve Lash Adjusters: Inspection
- To check valve lash adjusters, bleed adjuster by immersing in light oil. Insert Valve Lash Adjuster Tester (09276-70010) into valve lash adjuster plunger hole. Slide plunger up and down several times while pushing on check ball lightly.
- If plunger stroke exceeds .020" (.50 mm), repeat step 1). If plunger stroke exceeds limit after repeated bleeding, replace valve lash adjuster.
- If valve lash adjuster plunger stroke is within specification, use a leak-down tester to check valve lash adjuster. Apply 44 lbs. (20 kg) of pressure to plunger and measure leak-down speed after plunger has moved approximately .08" (2.0 mm). Standard leak-down time is 2-7 seconds with a plunger movement of .04" (1.0 mm).