Inspection (Camry & Celica)
- With camshaft housing removed, measure cylinder head contact surface for warpage using a straightedge and feeler gauge. Maximum warpage is .0031" (.080 mm). If warpage is greater than specification, replace camshaft housing.
- Check camshaft runout. Using dial indicator, set pointer on center journal. Rotate camshaft and measure total runout. Maximum runout is .0016" (.040 mm). If beyond specification, replace camshaft.
- Using micrometer, check camshaft lobe height for excessive wear. Standard lobe height is 1.533-1.537" (38.93-39.03 mm). Minimum lobe height is 1.527" (38.78 mm). If worn beyond specification, replace camshaft.
- Using micrometer and telescopic hole gauge, measure camshaft journals and camshaft housing bearing bores for excessive wear. Standard bearing-to-journal clearance is .0010-.0026" (.025-.067 mm). Maximum clearance is .004" (.10 mm). If clearance beyond specification, replace camshaft and/or housing.