Oil Pump: Installation
Reassemble pump and lubricate seal lip. Install new "O" ring in block and apply sealer to upper bolt. Install and tighten pump. To complete installation, reverse removal procedure.
OIL PUMP SPECIFICATIONS
| Application | Clearance In. (mm) | |
|---|---|---|
| Drive Gear-to-Crescent | ||
| Standard | .0087-.0098 (.221-.249) | |
| Wear Limit | .012 (.30) | |
| Driven Gear-to-Crescent | ||
| Standard | .0059-.0083 (.149-.211) | |
| Wear Limit | .012 (.30) | |
| Driven Gear-to-Body | ||
| Standard | .0035-.0059 (.088-.149) | |
| Wear Limit | .008 (.20) | |
| Gear Faces-to-Body | ||
| Standard | .0012-.0035 (.030-.088) | |
| Wear Limit | .0059 (.149) | |