Inspection After Removal
- Check valve seating condition at ordinary room temperatures. It should seat tightly.
- Check valve operation.
- Place a thread so that it is caught in the valve of the thermostat. Immerse fully in a container filled with water. Heat while stirring.
- The valve opening temperature is the temperature at which the valve opens and falls from the thread.
- Continue heating. Check the full-open lift amount.
- After checking the full-open lift amount, lower the water temperature and check the valve closing temperature.THERMOSTAT REFERENCE CHART
Thermostat Standard Valve opening temperature Refer to [Service Data and Specifications ]. Full-open lift amount Refer to [Service Data and Specifications ]. Valve closing temperature Refer to [Service Data and Specifications ]. - If valve seating at ordinary room temperature, or measured values are out of standard, replace water inlet and thermostat assembly.
NOTE: The full-open lift amount standard temperature is the reference value.