LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2012 >> Equator RMZ-4 >> Repair and Diagnosis (Single Page) >> Electrical >> Gauges >> Instrumentation/Driver Info./Horn >> Diagnostic Information and Procedures >> Power Supply and Ground Circuit Check [Combination Meter]

Power Supply and Ground Circuit Check [Combination Meter]

DIAGNOSIS PROCEDURE CHART

Step Action YES NO
CHECK FUSES 
Check for blown combination meter fuses.
Is the inspection result normal? 
GO TO 2 If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse.
POWER SUPPLY CIRCUIT CHECK 
  1. Disconnect combination meter connector M24.
G06443196Courtesy of SUZUKI OF AMERICA CORP.

  1. 2. Check voltage between combination meter harness connector M24 terminals 3, 16 and ground.

Is the inspection result normal? 
GO TO 3 Check harness for open between combination meter and fuse.
GROUND CIRCUIT CHECK 
  1. Turn ignition switch OFF.
G06443197Courtesy of SUZUKI OF AMERICA CORP.

  1. 2. Check continuity between combination meter harness connector M24 terminals 13, 23 and ground.

Is the inspection result normal? 
Inspection End. Check ground harness.