Battery: Work Flow
>>
Battery Diagnosis Without Exp-800 NI Or Gr8-1200 NI
>>
Charging Rates (Standard Charge)
Charging Rates (Standard Charge)
CHARGING RATE TABLE
Approximate charge condition
Charge current (A)
Charge time (h)
Fully charged
7
2
3/4 charged
2.5
1/2 charged
5
1/4 charged
7.5
Almost discharged
9
Completely discharged
10