Diagnosis Procedure
Regarding Wiring Diagram information, refer to INTERIOR ROOM LAMP CONTROL SYSTEM: WIRING DIAGRAM [WITH POWER DOOR LOCKS] .
DIAGNOSIS PROCEDURE CHART
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK BATTERY SAVER OUTPUT/POWER SUPPLY OUTPUT SDT
Is the inspection result normal? |
GO TO 2 | Replace BCM. Refer to [BCM (BODY CONTROL MODULE): REMOVAL AND INSTALLATION ] |
| 2 | CHECK BATTERY SAVER OUTPUT/POWER SUPPLY OPEN CIRCUIT
Is the inspection result normal? |
GO TO 3 | Repair the harness or connectors. |
| 3 | CHECK BATTERY SAVER OUTPUT/POWER SUPPLY SHORT CIRCUIT Check continuity between BCM connector M20 terminal 56 and ground. Is the inspection result normal? |
Replace the interior room lamp. Refer to [INTERIOR ROOM LAMP: REMOVAL AND INSTALLATION [WITH POWER DOOR LOCKS] ]. | Repair the harness or connectors. |