Air Bag Diagnostic System Check Flow
CAUTION:
- Be sure to perform AIR BAG DIAGNOSTIC SYSTEM CHECK before starting diagnosis according to each flow.
- When measurement of resistance or voltage is required in the flow, use a tester along with a correct terminal adapter from special tool (Connector test adapter kit).
- When a check for proper connection is required, refer to INSPECTION OF INTERMITTENT AND POOR CONNECTIONS .
- If an open circuit in the air bag wire harness damaged, connector or terminal is found, replace the wire harness, connectors and terminals as an assembly.
TROUBLESHOOTING CHART
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | Battery voltage check
.
Is it 10 - 14 V? |
Go to Step 2. | Proceed to BATTERY INSPECTION . |
| 2 | "AIR BAG" warning light check (6 times flushing check)
.
Does "AIR BAG" warning light flash 6 times? |
Go to Step 3. | Go to Step 4. |
| 3 | "AIR BAG" warning light check (turning off check)
.
Does "AIR BAG" warning light turn OFF, after flashing 6 times? |
Go to Step 5. | Go to Step 6. |
| 4 | "AIR BAG" warning light circuit check Does "AIR BAG" warning light come ON steady? |
Proceed to "AIR BAG" WARNING LIGHT COMES ON STEADY After inspect, go to Step 6. | Proceed to "AIR BAG" WARNING LIGHT DOES NOT COME ON . After inspect, go to Step 6. |
| 5 | DTC check
|
Air bag system is in good condition. | Check intermittent troubles referring to INSPECTION OF INTERMITTENT AND POOR CONNECTIONS
. If intermittent troubles are OK, check and repair applicable DTC flow and then repeat this flow. |
| 6 | DTC check
Is "NO CODES" displayed on SUZUKI scan tool? |
Substitute a known-good SDM and recheck. | Check and repair applicable DTC flow, and then repeat this flow. |