LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2008 >> SX4 LE, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Automatic Transmission) >> Repair Instructions >> Solenoid Valves (Shift Solenoid Valves and TCC Solenoid Valve) Inspection >> Resistance Check

Resistance Check

WARNING: This page is about a different variant/trim than selected.

Shift solenoid valve-A (No. 1), -B (No. 2) and TCC solenoid valve

Shift solenoid valve-A resistance 

Standard: 12 - 16 Ω at 20°C (68°F) 

Shift solenoid valve-B resistance 

Standard: 11 - 15 Ω at 20°C (68°F) 

TCC solenoid valve resistance 

Standard: 11 - 15 Ω at 20°C (68°F) 

Fig 1: Checking TCC Solenoid Valve Resistance
G04847797Courtesy of SUZUKI OF AMERICA CORP.