Instrument Cluster Indicator Lamps Diagnosis
INSTRUMENT CLUSTER INDICATOR LAMPS DO NOT OPERATE
| Step | Action | Value(s) | Yes | No |
|---|---|---|---|---|
| 1 | Check fuse F12 and Ef21. Is fuse F12 and Ef21 blown? |
- | Go to Step 2. | Go to Step 3. |
| 2 |
Is the repair complete? |
- | System OK | - |
| 3 |
Is the battery voltage equal to the specified value? |
11-14V | Go to Step 5. | Go to Step 4. |
| 4 | Repair the open power supply circuit to fuse F12 and Ef21. Is the repair complete? |
- | System OK | - |
| 5 |
Is the battery voltage equal to the specified value? |
11-14V | Go to Step 7. | Go to Step 6. |
| 6 | Repair the open circuit between fuses Ef21 and F12 and instrument cluster connectors B14, C4 and B10. Is the repair complete? |
- | System OK | - |
| 7 | Check the instrument cluster warning lamp bulbs. Are the bulbs OK? | - | Go to Step 9. | Go to Step 8. |
| 8 |
Is the repair complete? |
- | System OK | - |
| 9 | Replace the instrument cluster. Is the repair complete? |
- | System OK | - |