Combination Meter Symptom Diagnosis
Display and indicator lamps do not light up.
NOTE:
Fuse name (" ") is shown on the fuse box cover.
- "METER" fuse blown, then replace fuse to check for short.
- Power source circuit (between ignition switch and combination meter) open or short, then repair circuit.
- Wiring or grounding faulty, then repair circuit.
- Combination meter faulty, then replace combination meter.