LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2001 >> XL-7 Limited >> Repair and Diagnosis >> External Pages >> Different car >> Section 94 (Overhaul - A/T) >> Repair Instructions >> Pressure Control Solenoid Valves (Pressure Control Solenoid-A, Pressure Control Solenoid-B, Pressure Control Solenoid-C and TCC Solenoid Valve) >> Resistance check

Resistance check

WARNING: This page is about a different car, the 2004 Suzuki XL-7. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: Be very careful as dust etc. does not enter when pressure control solenoid valves are inspected. Measure resistance between pressure control solenoid valves (Pressure control solenoid-A, Pressure control solenoid-B, Pressure control solenoid-C and TCC solenoid) (1) terminals. If resistance is out of specification, replace valve body assembly.

Pressure control solenoid-A, Pressure control solenoid-B, Pressure control solenoid-C and TCC solenoid resistance 

  1. Standard: 5.0 - 5.6 ohms (at 20 °C (68 °F))
Fig 1: Measuring Resistance Between Pressure Control Solenoid Valves
G00761562Courtesy of SUZUKI OF AMERICA CORP.