Using Regulated DC Power Supply
WARNING: This page is about a different car, the 2004 Suzuki XL-7. However, it is still accessible from the selected car via links, so may be relevant.
- Connect pressure control solenoid valve (1) with regulated DC power supply (2) as shown in the figure.
- Turn regulated DC power supply switch ON, increase voltage of power supply keeping current within 1.0 A.
- Check that valve (3) moves gradually in arrow "A" direction as voltage increases.
- Check that valve (3) moves in arrow "B" direction as voltage decreases.
- Turn power supply switch OFF.
CAUTION:
Do not feed current 1.0 A or more, or pressure control solenoid will be burned out.