LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2024 >> Impreza Base >> Repair and Diagnosis >> Accessories & Equipment >> Exterior Lights >> Exterior Lights (Diagnostics) >> Fail Safe >> List

Fail Safe: List

If any of the following DTCs are stored, the system enters the fail safe mode.

DTC Failsafe operation Failsafe deactivation condition
B2900 ADB: Fixes both sides at Lo SRH: Fixes both sides at center AHL: Stops in malfunction position IG turned ON again
B2904 All function control continues After the condition returns to normal, turn to IG ON again
B2905 All function control continues
B2908 ADB: Fixes both sides at Lo SRH Right-side light: Stops in current position Left-side light: Fixed at center AHL: Current position - α° IG turned ON again
B2909 ADB: Fixes both sides at Lo SRH Right-side light: Fixed at center Left-side light: Stops in current position AHL: Current position - α°
B2910 ADB: Fixes both sides at Lo SRH Right-side light: Stops in current position Left-side light: Fixed at center AHL: Current position - α°
B2911 ADB: Fixes both sides at Lo SRH Right-side light: Fixed at center Left-side light: Stops in current position AHL: Current position - α°
B2916 ADB: Fixes both sides at Lo SRH: Fixes both sides at center AHL: Stops in malfunction position Normal conditions continue for 2 sec.
B2917 ADB: Fixes both sides at Lo SRH: Fixes both sides at center AHL: Stops in malfunction position
B2919 ADB: Fixes both sides at Lo SRH: Fixes both sides at center AHL: Stops in malfunction position IG turned ON again
B291A ADB: Fixes both sides at Lo SRH: Fixes both sides at center AHL: Stops in malfunction position Initialization work is performed again or fuse reset work is performed.
U0074 Both sides headlight Hi beam does not illuminate and lights are fixed at Lo. ADB: Fixes both sides at Lo SRH: Fixes both sides at center AHL: Stops in malfunction position IG turned ON again or normal conditions continue for 5 sec.
U1140 ADB: Fixes both sides at Lo SRH: Fixes both sides at center AHL: Stops in malfunction position IG turned ON again or normal conditions continue for 2 sec.
U1422
U0122 ADB: Fixes both sides at Lo SRH: Fixes both sides at center AHL: Stops in malfunction position
U0416
U0101 ADB: Fixes both sides at Lo SRH: Fixes both sides at center
U0402
U1235 ADB: Fixes both sides at Lo SRH: Fixes both sides at center
U1433