| Pipe |
Check the connection between pressure sensor and pipe. |
Replace the pressure sensor. |
| Check the connection between pipe and condenser. |
Check the O-ring at connection and tightening torque. If necessary, replace each part. |
| Condenser |
Check the welded part of condenser and core. |
Replace the condenser. |
| Hose (high-pressure) |
Check the connection between hose (high-pressure) and compressor. |
Check the O-ring at connection and tightening torque. If necessary, replace each part. |
| Check the connection between hose (high-pressure) and condenser. |
Check the O-ring at connection and tightening torque. If necessary, replace each part. |
| Check the connection between pressure sensor and hose (high pressure). |
Replace the pressure sensor. |
| Check the rubber part of the flexible hose and pipe seam.
CAUTION:
Carefully check the external surface of flexible hoses and pipes at approx. 25 mm (0.98 in) per second. Check the valve and cap in the service port. |
Replace the hose (high pressure). |
| Check the rubber seal of the valve and cap. If necessary, replace valve or cap. |
| Compressor |
Check the compressor pulley and vicinity of shaft seal.
CAUTION:
Some shaft seals will show a slight amount of leakage, about 3 g (0.1 oz) per year. This is not a problem.
|
Replace the compressor. |
| Hose (low-pressure) |
Check the connection between hose (low pressure) and expansion valve. |
Check the O-ring at connection and tightening torque. If necessary, replace each part. |
| Check the connection between hose (low pressure) and compressor. |
Check the O-ring at connection and tightening torque. If necessary, replace each part. |
| Check the rubber part of the flexible hose and pipe seam.
CAUTION:
Carefully check the external surface of flexible hoses and pipes at approx. 25 mm (0.98 in) per second.
|
Replace the hose (low pressure). |
| Check the valve and cap in the service port. |
Check the rubber seal of the valve and cap. If necessary, replace valve or cap. |
| Check the connection between hose (low pressure) and pipe. |
Check the O-ring and lock spring at the connection. If necessary, replace each part. |
| Evaporator |
Remove the drain hose from the heater case, and check the end part for 10 seconds or more. |
Replace the evaporator. |
| Check the air vent grille.
NOTE:
Turn the ignition switch to ON, and run the blower at high speed for approx. 1 minute. Stop the blower to check the air vent grille on the instrument panel. While moving the tester closer to the grille, run the blower for 1 or 2 seconds, then stop it. Check the grille at that position for at least 10 seconds.
|
Replace the evaporator. |