Related Lines, More Than 52 Ω And Less Than 62 Ω ((H) Advanced Safety Can_Stereo Camera)
Wiring diagram:
CAN communication system Ref. to WIRING SYSTEM>CAN COMMUNICATION SYSTEM>WIRING DIAGRAM .
NOTE:
When the measured resistance value is more than 52 Ω and less than 62 Ω, main wiring harness or related lines may be shorted to ground, or shorted to power supply line, or related lines may be open.
- CHECK BETWEEN RELATED LINES AND MAIN WIRING HARNESS
.
- Disconnect the stereo camera connector.
- Using a tester, measure the resistance between terminals in stereo camera connector.
Connector & terminal
(Rf21) No. 13 - (Rf21) No. 1:
Is the resistance 400 Ω or more?
Yes: A related line between stereo camera and main wiring harness is open, or main wiring harness is open at two places or more.
No: Go to 2.
- CHECK RELATED LINES
.
- Disconnect the central gateway Control Module connector.
- Using a tester, measure the resistance between the stereo camera connector and central gateway Control Module connector.
Connector & terminal
(Rf21) No. 13 - (i88) No. 34:
(Rf21) No. 1 - (i88) No. 33:
Is the resistance 10 Ω or more?
Yes: Repair or replace the open circuit of stereo camera related lines.
No: Check DTC of stereo camera. Ref. to EYESIGHT (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .