LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2022 >> Forester Limited >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrumentation System & Driver Information Center >> Combination Meter System >> Operation >> Self-Diagnosis Display Mode >> LCD/TFT Display Check

LCD/TFT Display Check

Check the LCD/TFT display.

NOTE:
  • The meter needle indicate 0 or the lowest position.
  • ILL indication illuminates at the same brightness as immediately before entering "LCD/TFT display check".
  • For model with normal meter, after No. 14 is displayed in the illumination order, the display is repeated from No. 1 again.
  • For model with color TFT meter, after No. 8 is displayed in the illumination order, the display is repeated from No. 1 again. The version display contents of the illumination order No. 1 varies depending on the vehicle.
  1. Press the trip reset switch.
  2. After a buzzer sounds for 0.5 seconds and "STEP3" is displayed on LCD/TFT, the LCD/TFT display check mode is initiated.
    • Model with normal meter
      G13873840Courtesy of SUBARU OF AMERICA, INC.
    • Model with color TFT meter
      Order TFT display Warning/indicator light Time (sec)
      1 Version display & color gradation Light OFF 10
      2 Black Light OFF 10
      3 Red Light OFF 10
      4 Green Light OFF 10
      5 Blue Light OFF 10
      6 White Light OFF 10
      7 Color gradation Light OFF 10
      8 Cross talking Light OFF 10