Push Button Ignition Switch: Inspection
- Check the continuity between the connector terminals.
Terminal No. Inspection conditions Standard 5 (SSW1) - 6 (GND) When the push switch is not pressed 1 MΩ or more 1 (SSW2) - 6 (GND) When the push switch is not pressed 1 MΩ or more 5 (SSW1) - 6 (GND) When the push switch is pressed Less than 1 Ω 1 (SSW2) - 6 (GND) When the push switch is pressed Less than 1 Ω - Check the push button start switch operation when battery voltage is applied between the connector terminals.CAUTION: When applying battery voltage, do not mix up the positive (+) side and the negative (-) side.
Incorrect polarity connection may cause LED damage inside the switch.Terminal No. Inspection conditions Specification 9 (SWIL) - 6 (GND) Connect battery to the terminals Character illumination lights up - Replace the push button start switch if it is found defective.