Multi Information Display Switch
- Measure the resistance between connector terminals.
- Models without EyeSight
Terminal No. Inspection conditions Standard 2 - 4 LEFT
UP
DOWN
RIGHTAll OFF Approx. 100 kΩ LEFT ON Less than 1 Ω UP ON Approx. 330 Ω DOWN ON Approx. 1, 000 Ω RIGHT ON Approx. 3, 110 Ω 3 - 4 ENTER
BACKAll OFF Approx. 100 kΩ ENTER ON Less than 1 Ω BACK ON Approx. 1, 000 Ω - Models with EyeSight
Terminal No. Inspection conditions Standard 2 - 7 LEFT
UP
DOWN
RIGHTAll OFF Approx. 100 kΩ LEFT ON Less than 1 Ω UP ON Approx. 330 Ω DOWN ON Approx. 1, 000 Ω RIGHT ON Approx. 3, 110 Ω 3 - 7 ENTER
BACKAll OFF Approx. 100 kΩ ENTER ON Less than 1 Ω BACK ON Approx. 1, 000 Ω
- Models without EyeSight
- Apply battery voltage between the connector terminals to check lighting condition of illumination inside the switch.CAUTION: When applying battery voltage, do not mix up the positive (+) side and the negative (-) side.CAUTION: Incorrect polarity connection may cause LED damage inside the switch.
Terminal No. Inspection conditions Specification 8 (+) - 9 (-) Apply battery voltage. Light ON - If it is found to be defective as a result of the inspection, replace the satellite switch assembly.