Refrigerant Recovery Procedure: Procedure
CAUTION:
- During operation, be sure to wear protective goggles and protective gloves.
- Connect the refrigerant recovery system with the manifold gauge set to discharge the refrigerant from the A/C system and recycle the gas.
- When recycling the discharged refrigerant, keep service cans on hand. Because the recovery rate with the recovery system is approx. 90%, service cans are necessary to charge the refrigerant.
- Follow the detailed operation procedure described in the operation manual attached to the refrigerant recovery system.
- Perform compressor oil return operation. Refer to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>COMPRESSOR OIL>PROCEDURE .
- Turn the ignition switch to OFF.
- Remove the collector cover. (Except for STI model) Refer to INTAKE (INDUCTION) (W/O STI)>COLLECTOR COVER>REMOVAL .
- Attach the manifold gauge set.
Preparation tool:
Manifold gauge set
- Check that all valves are fully closed.
- Install the low/high pressure hoses to the service ports on the low/high pressure sides of the vehicle respectively.CAUTION: Confirm that the connections are secure.
- Connect the center hose to the refrigerant recovery system.
Preparation tool:
Refrigerant recovery system
- Follow the operation manual attached to the refrigerant recovery system to collect the refrigerant.