LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2021 >> WRX Base >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Heater, Ventilator And A/C) (Service Information) >> Refrigerant Pressure with Manifold Gauge Set >> Procedure >> Check Refrigerant Gas Pressure

Check Refrigerant Gas Pressure

  1. Prepare the vehicle.
    NOTE: Check that the ambient temperature is 25 - 40°C (77 - 104°F) and that the humidity is 30% - 80%.
    • Place the vehicle in the shade and windless condition, and open the front hood.
    • Open the front windows and close all doors.
  2. Check the refrigerant pressure

    Preparation tool: 

    Manifold gauge set

    1. Connect the manifold gauge set, and start the engine.
    2. Set the vehicle to the following conditions.
      Item Condition
      Engine Warmed up (Engine coolant temperature indicator light: OFF)
      Air vent grille Shutter is fully open.
      A/C switch ON
      Temperature adjustment dial LO (MAX COOL)
      FRESH/RECIRC switch RECIRC
      Air flow control dial or switch VENT
      Fan dial 5/7 level
    3. In the condition of step (2), idle the engine for 30 minutes.
    4. Read the gauge values on both high pressure side and low pressure side for manifold gauge.
  3. Measure the air vent grille outlet opening temperature, ambient temperature and humidity.

    Preparation tool: 

    Thermometer and hygrometer

    NOTE: For outlet opening temperature, measure the average temperature of center grille assembly and side grille assembly.
  4. Check that the high and low pressures and outlet opening temperature for ambient temperature and humidity is within the standard value described in the chart below.
    G08316121Courtesy of SUBARU OF AMERICA, INC.
  5. Refer to "DIAGNOSIS WITH SYMPTOM" if the inspection result is not within the standard value. Refer to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET>INSPECTION>INSPECTION WITH PRESSURE SYMPTOM .