Evaporator Sensor: Inspection
- Prepare the vehicle.NOTE: Check that the ambient temperature is 25 - 40°C (77 - 104°F) and that the humidity is 30% - 80%.
- Place the vehicle in the workshop or in the shade and windless condition.
- Open all windows.
- Set the vehicle to the following conditions.
Item Condition Engine Idling Air vent grille Shutter is fully open. A/C switch OFF Temperature adjustment dial LO (MAX COOL) FRESH/RECIRC switch RECIRC Air flow control dial or switch VENT Fan dial 5/7 level - Using the Subaru Select Monitor, check evaporator temperature.NOTE: For detailed operation procedures, refer to "Application help".
- On "Start" display, select "Diagnosis".
- On "Vehicle selection" display, enter vehicle information and select "Confirmed".
- On "Main Menu" display, select "Each System".
- On "Select System" display, select "Air Conditioner" and select "Enter".
- On "Select Function" display, select "Data Monitor".
- From the data monitor item list, select "Evaporator Temperature".
- Idle the engine for 15 minutes, and then compare the air flow outlet temperature with "Evaporator Temperature".
Preparation tool:
Thermometer and hygrometer
NOTE: For outlet opening temperature, measure the average temperature of center grille assembly and side grille assembly. - Do the air flow outlet temperature and "Evaporator Temperature" differ by 3°C (5.4°F) or more?
- yes → Go to step 4).
- no → Evaporator sensor is normal.
- Check the evaporator sensor.
- Disconnect the connector.
- Measure the resistance between connector terminals.CAUTION: During inspection, be careful not to touch the sensor end in order to avoid misjudgment due to body temperature.
Preparation tool:
Circuit tester
Terminal No. Inspection conditions Standard 1 - 2 -20°C 15.37 - 16.62 kΩ -15°C 12.09 - 12.87 kΩ -10°C 9.576 - 10.05 kΩ -5°C 7.636 - 7.899 kΩ 0°C 6.132 - 6.256 kΩ 5°C 4.891 - 5.057 kΩ 10°C 3.928 - 4.113 kΩ 15°C 3.174 - 3.366 kΩ 20°C 2.581 - 2.77 kΩ 25°C 2.111 - 2.292 kΩ 30°C 1.737 - 1.907 kΩ 35°C 1.437 - 1.595 kΩ 40°C 1.195 - 1.34 kΩ - Replace the evaporator sensor if the inspection result is not within the standard value.