Ambient Sensor: Inspection
- Visually check the ambient sensor for dirt or damage, and clean or replace as necessary.
- Measure the resistance between connector terminals.CAUTION: During inspection, be careful not to touch the sensor end in order to avoid misjudgement due to body temperature.
Terminal No. Inspection conditions Standard 2 - 1 10°C (50°F) 3.09 - 3.66 kΩ 15°C (59°F) 2.47 - 2.86 kΩ 20°C (68°F) 1.99 - 2.25 kΩ 25°C (77°F) 1.62 - 1.79 kΩ 30°C (86°F) 1.29 - 1.46 kΩ 35°C (95°F) 1.04 - 1.20 kΩ 40°C (104°F) 0.84 - 0.99 kΩ 45°C (113°F) 0.68 - 0.82 kΩ 50°C (122°F) 0.56 - 0.68 kΩ 55°C (131°F) 0.46 - 0.57 kΩ 60°C (140°F) 0.38 - 0.48 kΩ - Replace the ambient sensor if the inspection result is not within the standard value.