Diagnosis 1
WARNING: This page is about a different variant/trim than selected.
Judgment value
JUDGMENT VALUE SPECIFICATIONS - DIAGNOSIS 1
| Malfunction Criteria |
Threshold Value |
| Output duty to drive circuit |
95% or more |
Time needed for diagnosis:
- Engine speed 500rpm or more: 2000 ms
- Engine speed less than 500rpm: 5000 ms