Check Related Parts
WARNING: This page is about a different variant/trim than selected.
| Part |
Inspection |
| Wire harness and connector between the inverter and Motor resolver |
Check for short circuit between Wire harness and +B side |
| Resolver, Wire harness, connector |
Check the resistance including the resolver and Wire harness, resistance between the parts and chassis ground, and connecting condition of the connector |
| Wire harness |
Check Wire harness unit for open and short circuit |
| Part |
Inspection |
| Check Power cable connection |
Check connecting condition of the cable from the inverter to the motor |
| Motor, Power cable |
Measure internal resistance of the motor (including cable) and insulation resistance between the motor and chassis ground to check for open or short circuit |
| Part |
Inspection |
| Wire harness and connector between the inverter and Generator resolver |
Check for short circuit between Wire harness and +B side |
| Resolver, Wire harness, connector |
Check the resistance including the resolver and Wire harness, resistance between the parts and chassis ground, and connecting condition of the connector |
| Wire harness |
Check Wire harness unit for open and short circuit |
| Part |
Inspection |
| Check Power cable connection |
Check connecting condition of the cable from the inverter to the generator |
| Generator, Power cable |
Measure internal resistance of the generator (including cable) and insulation resistance between the generator and chassis ground to check for open or short circuit |
| Part |
Inspection |
| HSDN terminal |
Check for open or short circuit between HSDN terminals with READY OFF (IG ON) |
| Hybrid vehicle control ECU assembly, inverter, Wire harness |
Check Hybrid vehicle control ECU assembly, inverter and Wire harness for open and short circuit |
| Part |
Inspection |
| Inspection of inverter +B low voltage power supply system |
Inspection of inverter overcurrent malfunction due to voltage decrease of +B (low voltage system) |
| Communication error between Hybrid vehicle control ECU assembly and MG ECU in Inverter with converter assembly |
Inspection of inverter overcurrent malfunction due to communication error |
| Inspection of short circuit to ground for the inverter +B low voltage power supply system |
- |
| Part |
Inspection |
Procedure |
| High voltage system from HV battery to the inverter |
Check the connecting condition and open circuit |
1 - 2, 6 - 8 |
| Service plug |
Check the connecting condition and open circuit |
3 - 4 |
| EV battery fuse |
Check the open circuit |
5 |
| System main relay |
Check the operation condition as relay |
9 - 12 |
| Part |
Inspection |
| Grille clogging, coolant amount, coolant hose, HV radiator fan |
Check overheat due to Hybrid cooling system malfunction. |
| Inverter coolant temperature sensor (inverter built-in) |
Check malfunction of temperature sensor |
| Check coolant freeze |
Through the freeze frame data values, check possibility of the hybrid coolant freeze when the DTC was stored. |