Diagnostic Method
Difference between the current power supply voltage ratio and the previous power supply voltage ratio of brake stroke sensor input 2 and brake stroke sensor power supply 2 is higher than 8.48%.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| ABS (Current brake stroke sensor input 2/Brake stroke sensor power supply 2 - Last brake stroke sensor input 2/Brake stroke sensor power supply 2) | More than 0.0848 |
Time needed for diagnosis: 200 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.