Diagnostic Method
Power supply voltage ratio of brake stroke sensor input 2 and brake stroke sensor power supply 2 is less than 0.06.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Brake stroke sensor input 2/Brake stroke sensor power supply 2 | Less than 0.06 |
Time needed for diagnosis: 200 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.