Diagnostic Method
An open or insufficient current is detected in the solenoid.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Case 1 Output duty Cycle-Current MAP A
NOTE:
Threshold is Current
|
Less than Table 1 A |
| Case 2 Output duty Cycle-Current MAP B
NOTE:
Threshold is Current
|
Less than Table 2 A |
| Case 3 Solenoid Valve high side voltage |
More than 5.46 V |
SEPARATION LOCK VALVE OUTPUT DUTY CYCLE-CURRENT MAP A (LOW THRESHOLD MAP) SPECIFICATION
| Output Duty (%) | 14.82 | 18.03 | 20.95 | 26.95 | 44.97 | 75.03 | 93.28 | 114.44 | 135.37 |
| Threshold (A) | 0.00 | 0.05 | 0.10 | 0.20 | 0.50 | 1.00 | 1.30 | 1.65 | 2.00 |
SEPARATION LOCK VALVE OUTPUT DUTY CYCLE-CURRENT MAP B (LOW THRESHOLD MAP) SPECIFICATION
| Output Duty (%) | 30 | 30 | 34.34 | 43.19 | 53.77 | 86.38 | 107.54 |
| Threshold (A) | 0.000 | 0.085 | 0.100 | 0.130 | 0.165 | 0.260 | 0.330 |
Time needed for diagnosis:
- Case 1: 7 times
- Case 2: 54 ms
- Case 3: 54 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.