Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Case 1 Power supply for Brake Fluid Pressure Control Solenoid |
More than 9.13 V |
| Command to Brake Fluid Pressure Control Solenoid Valve power supply relay | Closed |
| Brake Fluid Pressure Control Solenoid Valve power supply relay | Closed |
| Serial communication with IC1 | Valid |
| Solenoid Valve low side operating | ON |
| Current | Less than 2.3 A |
| ABS (Current target current - Last target current) | 0.20 A or less |
| Output duty cycle | More than 0% |
| ABS (Current Power supply for linear Solenoid Valve - Last Power supply for linear Solenoid Valve) | 1 V or less |
| Solenoid Valve open current correlation | Stored |
| Current monitor | Normal |
| Case 2 Power supply for Brake Fluid Pressure Control Solenoid |
More than 9.13 V |
| Command to Brake Fluid Pressure Control Solenoid Valve power supply relay | Closed |
| Brake Fluid Pressure Control Solenoid Valve power supply relay | Closed |
| Serial communication with IC1 | Valid |
| Solenoid Valve low side operating | ON |
| Current | Less than 2.3 A |
| ABS (Current target current - Last target current) | 0.20 A or less |
| Output duty cycle | More than 0% |
| Current monitor | Normal |
| ABS (Current Power supply for linear Solenoid Valve - Last Power supply for linear Solenoid Valve) | More than 1 V |
| or Solenoid Valve open current correlation |
Not Stored |
| Case 3 Command to Brake Fluid Pressure Control Solenoid Valve power supply relay |
Closed |
| Brake Fluid Pressure Control Solenoid Valve power supply relay | Closed |
| Solenoid Valve low side operating | ON |
| Serial communication with IC1 | Valid |
| Output duty cycle | 0% |
| Current monitor | Normal |
| Current | Less than 0.20 A |