Diagnostic Method
An open or insufficient current is detected in the solenoid.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Case 1 Output duty Cycle-Current MAP A
NOTE:
Threshold is Current
|
Less than Table 1 A |
| Case 2 Output duty Cycle-Current MAP B
NOTE:
Threshold is Current
|
Less than Table 2 A |
| Case 3 Solenoid Valve high side voltage |
More than 5.46 V |
PRESSURE-REDUCING LINEAR SOLENOID VALVE OUTPUT DUTY CYCLE-CURRENT MAP A (LOW THRESHOLD MAP) SPECIFICATION
| Output Duty (%) | 19.4 | 22.04 | 24.44 | 29.37 | 44.2 | 68.93 | 83.94 | 101.34 |
| Threshold (A) | 0.00 | 0.05 | 0.10 | 0.20 | 0.50 | 1.00 | 1.30 | 1.65 |
PRESSURE-REDUCING LINEAR SOLENOID VALVE OUTPUT DUTY CYCLE-CURRENT MAP B (LOW THRESHOLD MAP) SPECIFICATION
| Output Duty (%) | 30 | 30 | 30.9 | 38.64 | 47.67 | 77.28 | 95.34 | 154.56 |
| Threshold (A) | 0.000 | 0.097 | 0.100 | 0.130 | 0.165 | 0.260 | 0.330 | 0.52 |
Time needed for diagnosis:
- Case 1: 14 times
- Case 2: 54 ms
- Case 3: 54 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.