Diagnostic Method
Brake pedal stroke sensor assembly state is invalid.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Case 1 Brake stroke sensor power supply # |
Less than 4.74 V or More than 5.23 V |
| Case 2 Brake stroke sensor input #/Brake stroke sensor power supply # |
Less than 0.06 or More than 0.94 |
| Case 3 ABS (Current brake stroke sensor input #/Brake stroke sensor power supply # - Last brake stroke sensor input #/Brake stroke sensor power supply #) |
More than 0.0848 |
| Case 4 Zero Position Correlation |
Not Completed |
| Brake stroke sensor input 1/Brake stroke sensor power supply 1 + | More than 1.1 |
| Brake stroke sensor input 2/Brake stroke sensor power supply 2 | or Less than 0.9 |
| Case 5 Zero Position Correlation |
Completed |
| Brake stroke sensor input 2/Brake stroke sensor power supply 2 | Exceeds Brake stroke sensor input 2/Brake stroke sensor power supply 2_Max (Table 1 Value) or Below Brake stroke sensor input 2/Brake stroke sensor power supply 2_Min (Table 1 Value) |
BRAKE STROKE SENSOR SPECIFICATION
| Brake stroke sensor input 1/Brake stroke sensor power supply 1 | 0 | 0.19 | 0.21 | 0.61 | 1 |
| Brake stroke sensor input 2/Brake stroke sensor power supply 2_Min | 0.9377 | 0.7871 | 0.754 | 0.0937 | -0.5502 |
| Brake stroke sensor input 2/Brake stroke sensor power supply 2_Max | 1.079 | 0.8379 | 0.8125 | 0.5695 | 0.3333 |
Time needed for diagnosis: 200 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.